This model which is highly recommended in worksite environment is very fuctional for CRS1 and CRS2 productions. The production principle is designed cut Semi-continuous.
During production process, liquid material pumps such as bitumen, solution, solvent, DOP, latex works with the help of invertor and has capability of including necessary amount of material to the process. Also a flowmeter can be placed behind each pump and necessary amount the system needs determined by flowmeter is provided.
The bitumen and solvent sifts through static mixer in definite proportions according to the receipt so the bitumen has the deserved penetration value.
The solution is prepared in tanks made of poliproetilen (PP3) material. A measurement unit is designed for other admixture materials of the receipt (such as Emulgator, Acid, Stabilizer). Thus, all admixtures are easily measured and definetely sent to the solution tanks. There are two different equipments within the body in order to heat water for the solution. Heats the external cold water through electric heaters or by replacing plate heat exchanger in the exit of the emulsion product. Time and energy is saved by this contemporary application. The solution which the temperature and pH value had become proper and mixed homogenously, reaches the colloidal mill passing through the flow meter by 316 quality stainless steal, in-line vertical centrifuge pump.
The bitumen and solution which reaches the mill mixes up and speedly fragmentized and form a perfect emulsion. The samples taken from the sample valves are sent to bitumen emulsion stock tanks after being approved by the test. The whole process is controlled and managed automatically and manually by a PLC.
SPECIFICATIONS | MODELS | |||||
---|---|---|---|---|---|---|
EMTES 3 | EMTES 8 | EMTES 12 | EMTES 20 | CBTES 30 | LABTES | |
Capacity (t/sa) | 3 | 8 | 12 | 20 | 30 | 1 |
Production Type | ||||||
Party (Semi-Continuous) | √ | x | √ | √ | x | Cut-Back (Continuous Production) |
Continuous (Inline) | x | x | x | x | x | |
Continuous (Continuous) | √ | √ | √ | √ | √ | |
Portability | Container 20’ & 40' | W x L x H 2,4 x 7,5 x 2,6 | Container 20' | Container 40' | Container 20' | Mobile |
Solution Tank Number | 1 & 2 | 1 | 1 & 2 | 2 | x | 1 |
Solution Dosage | Flowmetre | Flowmetre | Flowmetre | Flowmetre | x | Digital Counter |
Bitumen Dosage | Flowmetre | Digital Counter | Flowmetre | Flowmetre | Flowmetre | Digital Counter |
Mill Type | GAP Adjusted Variable Speed | GAP Adjusted Fix Speed | GAP Adjusted Variable Speed | GAP Adjusted Variable Speed | x | GAP Adjusted Variable Speed |
Granule Dimension(μm) | 0.1 | 0.1 | 0.1 | 0.1 | x | 0.1 |
Solvent Dosage | Flowmetre | x | Flowmetre | Flowmetre | Flowmetre | x |
Emulgator & Acid Dosage | Loadcell | Loadcell | Loadcell | Loadcell | x | x |
Heating | Electrical/ Hot Oil | Electrical/ Hot Oil | Electrical/ Hot Oil | Electrical/ Hot Oil | Electrical/ Hot Oil | Electrical |
Control | Manuel / Full Automatic | Manuel / Full Automatic | Manuel / Full Automatic | Manuel / Full Automatic | Manuel / Full Automatic | Manuel / Full Automatic |
Additional Equipments | DOP Latex | DOP Latex | DOP Latex | DOP Latex | DOP Latex | DOP Latex |
Electric Heater | √ | x | √ | √ | √ | x |
Heat Exchanger | √ | x | √ | √ | √ | x |
Total Power (kW) | 75 | 61 | 90 | 105 | 30 | 5 |